The PLC chassis comes in different sizes according to the:


A) size of the program.
B) type of I/O modules used.
C) number of slots they contain.
D) all of these.

E) A) and C)
F) C) and D)

Correct Answer

verifed

verified

The location of a specific input or output field device is identified by the processor by means of its:


A) voltage rating.
B) current rating.
C) wattage rating.
D) address.

E) C) and D)
F) B) and C)

Correct Answer

verifed

verified

Light is used in I/O modules to separate the real-world electrical signals from the PLC internal electronic system.

A) True
B) False

Correct Answer

verifed

verified

Most PLC programming software will allow you to develop programs on another manufacturer's PLC.

A) True
B) False

Correct Answer

verifed

verified

False

The most common form of memory used to store,back up,or transfer PLC programs is:


A) RAM
B) Flash EEPROM
C) EEPROM
D) both b and c

E) C) and D)
F) A) and D)

Correct Answer

verifed

verified

The I/O system provides an interface between:


A) input modules and output modules.
B) the CPU and field equipment.
C) the CPU and I/O rack.
D) the I/O rack and I/O modules.

E) A) and C)
F) B) and C)

Correct Answer

verifed

verified

B

Electrical noise usually causes permanent operating errors.

A) True
B) False

Correct Answer

verifed

verified

False

I/O modules are normally installed or removed while the PLC is powered.

A) True
B) False

Correct Answer

verifed

verified

Volatile memory elements can be classified as those that:


A) do not retain stored information when the power is removed.
B) retain stored information when the power is removed.
C) do not require a battery backup.
D) both b and c.

E) B) and D)
F) B) and C)

Correct Answer

verifed

verified

I/O modules are keyed to prevent unauthorized personnel from removing them from the I/O rack.

A) True
B) False

Correct Answer

verifed

verified

In event of a power interruption,a(an) _____ is used in some processors to provide power to the RAM.


A) inductor
B) capacitor
C) transistor
D) resistor

E) C) and D)
F) A) and B)

Correct Answer

verifed

verified

The schematic diagram of Figure 2-6 is an example of how a PLC output module is connected to: The schematic diagram of Figure 2-6 is an example of how a PLC output module is connected to:   A) isolate the load from the controller. B) control a high resistance load. C) vary the speed of a motor. D) control a high current load.


A) isolate the load from the controller.
B) control a high resistance load.
C) vary the speed of a motor.
D) control a high current load.

E) None of the above
F) B) and C)

Correct Answer

verifed

verified

Which of the following devices can be used for switching the output of a discrete DC output module?


A) Transistor.
B) Triac.
C) Relay.
D) either a or c.

E) A) and B)
F) None of the above

Correct Answer

verifed

verified

Analog signals can have only two states.

A) True
B) False

Correct Answer

verifed

verified

For the block diagram of the input module shown,Section #1 represents the ____ and #2 the ____ For the block diagram of the input module shown,Section #1 represents the ____ and #2 the ____   A) AC,DC. B) DC,AC. C) power,logic. D) logic,power.


A) AC,DC.
B) DC,AC.
C) power,logic.
D) logic,power.

E) A) and C)
F) C) and D)

Correct Answer

verifed

verified

A redundant PLC system is configured using two processors.

A) True
B) False

Correct Answer

verifed

verified

A/An ____ input or output is a continuously variable signal within a designated range.


A) discrete
B) digital
C) BCD
D) analog

E) All of the above
F) A) and D)

Correct Answer

verifed

verified

If you had a hand-held programming terminal from one manufacturer you can program only that manufacture's PLC using it.

A) True
B) False

Correct Answer

verifed

verified

The processor module of the PLC is where the:


A) ladder logic program is stored.
B) input connections are made.
C) output connections are made.
D) sensors are located.

E) A) and C)
F) B) and D)

Correct Answer

verifed

verified

Hot swappable I/O modules are designed to be changed with the power on and the PLC operating.

A) True
B) False

Correct Answer

verifed

verified

Showing 1 - 20 of 84