A fundamental responsibility of radiographers is to ensure that each radiation exposure upholds the ALARA concept.ALARA stands for:


A) as low as reasonably achievable.
B) as long as radiograph is acceptable.
C) acceptable limits allowed for radiographic attempts.
D) attempts to lessen all radiographic allowances.

E) A) and B)
F) A) and D)

Correct Answer

verifed

verified

Collimation of the x-ray beam prompts which two of the following? (Select all that apply.)


A) A decrease in radiographic contrast
B) An increase in radiographic contrast
C) A decrease of scatter radiation
D) An increase of scatter radiation

E) A) and D)
F) B) and C)

Correct Answer

verifed

verified

Radiographers can control voluntary motion by:


A) using a high kVp.
B) increasing the length of exposure time.
C) performing the examination in the recumbent position.
D) giving clear instruction to the patient.

E) A) and B)
F) A) and C)

Correct Answer

verifed

verified

Which term refers to restriction of the exposure field?


A) Collimation
B) Filter
C) Shuttering
D) Central ray (CR)

E) A) and C)
F) B) and C)

Correct Answer

verifed

verified

Blood and body fluid recommendations are issued by the:


A) CDC.
B) ASRT.
C) ARRT.
D) JCAHO.

E) All of the above
F) A) and C)

Correct Answer

verifed

verified

The easiest and most convenient method of preventing the spread of microorganisms is:


A) wearing PPE.
B) following cough etiquette protocols.
C) handwashing.
D) proper handling of sharps.

E) B) and C)
F) All of the above

Correct Answer

verifed

verified

C

Which of the following radiographic examinations would give a male patient the highest gonad dose?


A) Limb
B) Skull
C) Pelvis
D) Lumbar spine

E) A) and B)
F) None of the above

Correct Answer

verifed

verified

The Radiography Practice Standards are written and maintained by the:


A) American Registry of Radiologic Technologists.
B) American Medical Association.
C) American Society of Radiologic Technologists.
D) Joint Commission on Education in Radiologic Technology.

E) A) and B)
F) A) and C)

Correct Answer

verifed

verified

How often should the radiographic tabletop be cleaned?


A) Only when visibly soiled
B) Weekly
C) Daily
D) After every procedure/patient

E) None of the above
F) C) and D)

Correct Answer

verifed

verified

All are guidelines for gonad shielding,except:


A) the gonads lie in the primary beam.
B) shielding is used when it will not compromise the exam objective.
C) patients with reasonable reproductive potential should be shielded.
D) gonad shields are only needed for pediatric patients.

E) C) and D)
F) A) and B)

Correct Answer

verifed

verified

The general goal for central ray placement is:


A) parallel with the structure of interest.
B) perpendicular to the structure of interest.
C) angled along the long axis of the part of interest.
D) angled against the long axis of the part of interest.

E) None of the above
F) B) and D)

Correct Answer

verifed

verified

Which type of accessory equipment reduces the amount of scatter and off-focus radiation that reaches the image receptor?


A) Compensating filter
B) Grid
C) Sandbag
D) Sponge

E) None of the above
F) B) and D)

Correct Answer

verifed

verified

All of the following are affected by the SID used for a radiographic image,except:


A) spatial resolution.
B) magnification of the anatomy in the image.
C) patient dose.
D) contrast resolution.

E) B) and C)
F) C) and D)

Correct Answer

verifed

verified

D

Gonad shielding is required when the gonads lie within ____ cm of the primary x-ray field.


A) 3
B) 5
C) 6
D) 8

E) A) and B)
F) A) and C)

Correct Answer

verifed

verified

Information that must be included on all radiographic images includes all of the following except:


A) right or left side marker.
B) patient's name or ID number.
C) radiographer's name.
D) date of exam.

E) A) and B)
F) B) and C)

Correct Answer

verifed

verified

C

The central or principle beam of x-rays is termed the:


A) center beam (CB) .
B) image beam (IB) .
C) central ray (CR) .
D) image receptor (IR) .

E) B) and C)
F) A) and B)

Correct Answer

verifed

verified

What is the most common image receptor general position?


A) Diagonal
B) Crosswise
C) Lengthwise
D) Vertical

E) B) and C)
F) A) and C)

Correct Answer

verifed

verified

Which of the following radiographic examinations would give a female patient the highest gonad dose?


A) Limb
B) Skull
C) Pelvis
D) Lumbar spine

E) A) and D)
F) C) and D)

Correct Answer

verifed

verified

The simplest and most common shape of compensating filter is the:


A) wedge.
B) trough.
C) double-wedge.
D) Boomerang.

E) A) and B)
F) A) and C)

Correct Answer

verifed

verified

The metric conversion of 40 inches is _____ cm.


A) 16
B) 18
C) 90
D) 102

E) A) and D)
F) A) and C)

Correct Answer

verifed

verified

Showing 1 - 20 of 32