Refer to the exhibit. Refer to the exhibit.   An integrator needs to add an FCoE connection to the server profile, but the FCoE connection type is not available. What is the likely cause of this issue? A)  FCoE capable interconnect modules are not installed in the Synergy frame B)  Defined FCoE network is not associated with a SAN or does not have VLAN Id defined C)  A FCoE connection is not available, as there is no LIG configured for FCoE connectivity D)  The FCoE connection has not been added as a Fibre Channel connection within a server profile An integrator needs to add an FCoE connection to the server profile, but the FCoE connection type is not available. What is the likely cause of this issue?


A) FCoE capable interconnect modules are not installed in the Synergy frame
B) Defined FCoE network is not associated with a SAN or does not have VLAN Id defined
C) A FCoE connection is not available, as there is no LIG configured for FCoE connectivity
D) The FCoE connection has not been added as a Fibre Channel connection within a server profile

E) B) and C)
F) A) and B)

Correct Answer

verifed

verified

Is this a correct statement about how containers fit within a DevOps model? Containers help to provide simple deployment and scaling for applications in production, but only if the customer deploys them within an orchestration solution.


A) Yes
B) No

C) A) and B)
D) undefined

Correct Answer

verifed

verified

  A customer is expanding its Synergy environment from one rack with a 3-frame master/satellite configuration to five racks (15 Synergy Frames)  with identical hardware configurations. What must the integrator do to perform this Synergy expansion? A)  Create new Logical Enclosure (LE) , Logical Enclosure Group (LIG) , and Enclosure Group (EG)  for each rack B)  Create a new Logical Enclosure (LE)  for each rack using existing templates C)  Re-home the Logical Enclosure (LE)  using the edited Enclosure Group (EG)  and Logical Interconnect Group (LIG)  D)  Perform hardware discovery from the console, and copy the Logical Enclosure (LE) A customer is expanding its Synergy environment from one rack with a 3-frame master/satellite configuration to five racks (15 Synergy Frames) with identical hardware configurations. What must the integrator do to perform this Synergy expansion?


A) Create new Logical Enclosure (LE) , Logical Enclosure Group (LIG) , and Enclosure Group (EG) for each rack
B) Create a new Logical Enclosure (LE) for each rack using existing templates
C) Re-home the Logical Enclosure (LE) using the edited Enclosure Group (EG) and Logical Interconnect Group (LIG)
D) Perform hardware discovery from the console, and copy the Logical Enclosure (LE)

E) All of the above
F) B) and D)

Correct Answer

verifed

verified

An integrator is installing three Synergy frames in different locations for a customer. As part of the installation, the customer requests a single monitoring dashboard that shows the current hardware status, warranty status, and open support cases of all three frames. Which configuration steps must the integrator perform to provide the customer with this functionality?


A) Enable Remote Support and Insight Online Integration in the Composer UI
B) Install Insight Remote Support Advanced, and integrate it with HPE Global Dashboard
C) Configure OneView with iLO Amplifier pack
D) Activate iLO Federation on all installed compute nodes

E) C) and D)
F) A) and D)

Correct Answer

verifed

verified

The architect must design Microsoft Storage Spaces Direct on HPE infrastructure, in order to meet customer requirements. Is this a correct principle that the architect must consider? Set up RAID 1 or mirroring on the drives with OS volumes.


A) Yes
B) No

C) A) and B)
D) undefined

Correct Answer

verifed

verified

Is this how the Composable Fabric handles traffic at Layer 2? It sees if the traffic matches an affinity and forwards the traffic on a dedicated path for that affinity.


A) Yes
B) No

C) A) and B)
D) undefined

Correct Answer

verifed

verified

Is this a benefit of the HPE Nimble plug-in for vCenter? simplified management for restoring VM clones from vCenter


A) Yes
B) No

C) A) and B)
D) undefined

Correct Answer

verifed

verified

What is the main difference between HPE SimpliVity 2600 and HPE SimpliVity 380?


A) HPE SimpliVity 380 is shipped in 5-node cluster configuration, while SimpliVity 2600 offers flexible expanding
B) HPE SimpliVity 380 integrates with Hyper-V only, while HPE SimpliVity 2600 supports any virtualization platform
C) HPE SimpliVity 380 is licensed per virtual machine, while HPE SimpliVity 2600 is licensed per capacity
D) HPE SimpliVity 380 uses hardware deduplication, while HPE SimpliVity 2600 uses software deduplication

E) A) and C)
F) All of the above

Correct Answer

verifed

verified

Is this a reason to use VVols on an HPE storage array to support a VMware vSphere environment? because VVol acts as plug-ins, integrating array monitoring and management on vCenter


A) Yes
B) No

C) A) and B)
D) undefined

Correct Answer

verifed

verified

A customer is virtualizing some of their data center production networks with NSX. You are helping with the plan. Is this a valid design for routing within the NSX solution? routing traffic between VXLANs (logical networks) locally on each ESXi host by deploying a distributed logical router (DLR) to an edge cluster


A) Yes
B) No

C) A) and B)
D) undefined

Correct Answer

verifed

verified

A customer is unable to boot to a 3.5TB volume created and presented to a compute node. What is likely preventing the boot?


A) The system is set to UEFI instead of Legacy Boot mode
B) The system is set to Legacy Boot mode instead of UEFI
C) Boot volumes larger than 2.2TB are not supported on Synergy
D) Boot volumes larger than 3TB are not supported on HPE Synergy

E) A) and B)
F) All of the above

Correct Answer

verifed

verified

A customer has a Red Hat OpenShift Container Platform (OCP) solution. You suggest deploying HPE Nimble and the HPE CSI Driver. With this proposal, can HPE Nimble fulfill this role for the solution? Host images for the private registry.


A) Yes
B) No

C) A) and B)
D) undefined

Correct Answer

verifed

verified

Is this a benefit of using NetEdit to manage ARubaOS-CX switches? API-based scripting of the network infrastructure


A) Yes
B) No

C) A) and B)
D) undefined

Correct Answer

verifed

verified

A Synergy integrator is unable to assign an HPE 3PAR Virtual Volume to a new server profile in HPE Composer. The Virtual Volume has been previously assigned to another profile. Which setting in HPE Composer is preventing the integrator from assigning the volume to the new profile?


A) private, in the volume properties
B) shared, in the volume properties
C) private, in the storage pool properties
D) shared, in the storage pool properties

E) A) and D)
F) B) and C)

Correct Answer

verifed

verified

Is this a use case for using virtualization instead of a bare metal or containerized deployment? Simplifying workload deployment using familiar vSphere or Hyper-V tools


A) Yes
B) No

C) A) and B)
D) undefined

Correct Answer

verifed

verified

Your customer is struggling to make their data center, which is already 70% virtualized, more automated and sofware-defined. IT resists further virtualization due to the special requirements of some workloads. Is this an approach that you should recommend to decision makers for meeting their goals? Use OneView's templates and Unified API to treat both virtual and physical infrastructure as fluid resource pools.


A) Yes
B) No

C) A) and B)
D) undefined

Correct Answer

verifed

verified

Is this a benefit of using the HPE OneView RESTful API to monitor and manage HPE infrastructure? customers can issue API calls using their choice of programming languages


A) Yes
B) No

C) A) and B)
D) undefined

Correct Answer

verifed

verified

A customer has a datacenter with 3-frame Master/Satellite Synergy solution. They plan to add two additional frames to the remote datacenter, but they want to have a single management tool. How should the integrator set up the management of the datacenter?


A) Add two frames from the remote datacenter as remote enclosures using existing Composer
B) Install one Composer in every frame in both local and remote datacenter
C) Deploy one Composer in each site and link them together
D) Connect the management links with fibre cables if the distance between datacenters is more than 500m

E) B) and D)
F) B) and C)

Correct Answer

verifed

verified

Which storage solution can be used for volume provisioning using HPE Composer?


A) MSA 2040
B) HPE StoreEasy 1560
C) HPE 3PAR StoreServ
D) HPE XP7 Storage

E) All of the above
F) B) and D)

Correct Answer

verifed

verified

Refer to the exhibit. Refer to the exhibit.   A customer with the design shown needs to perform an in-place upgrade to its environment to scale the two-frame single homed Multimodule Link Aggregation Group (MLAG)  configuration to a three-frame configuration. The new frame needs to provide a redundant 20Gb connection for the compute module ports in Fabric 3. Which interconnect modules should the integrator use in Frame 3? A)  HPE Virtual Connect SE 40Gb F8 module in bay 3 and HPE Virtual Connect SE 40Gb F8 Module in bay 6 B)  HPE Synergy 10Gb Interconnect Link Module in bay 3 and HPE Synergy 10Gb Interconnect Link Module in bay 6 C)  HPE Synergy 20Gb Interconnect Link Module in bay 3 and HPE Synergy 20Gb Interconnect Link Module in bay 6 D)  HPE Synergy 20Gb Interconnect Link Module in bay 3 and HPE Synergy 10Gb Interconnect Link Module in bay 6 A customer with the design shown needs to perform an in-place upgrade to its environment to scale the two-frame single homed Multimodule Link Aggregation Group (MLAG) configuration to a three-frame configuration. The new frame needs to provide a redundant 20Gb connection for the compute module ports in Fabric 3. Which interconnect modules should the integrator use in Frame 3?


A) HPE Virtual Connect SE 40Gb F8 module in bay 3 and HPE Virtual Connect SE 40Gb F8 Module in bay 6
B) HPE Synergy 10Gb Interconnect Link Module in bay 3 and HPE Synergy 10Gb Interconnect Link Module in bay 6
C) HPE Synergy 20Gb Interconnect Link Module in bay 3 and HPE Synergy 20Gb Interconnect Link Module in bay 6
D) HPE Synergy 20Gb Interconnect Link Module in bay 3 and HPE Synergy 10Gb Interconnect Link Module in bay 6

E) All of the above
F) B) and C)

Correct Answer

verifed

verified

Showing 61 - 80 of 123